Comfort Sync (quiet recovery)
Spaces out and softens corrections so a fixed thermostat does not look like an instant robot.
- Watches
- Recent wall-touch count, time since the last defender command, and how far the room is above target.
- Effect
- Holds the correction until the chosen calm moment, then lets a softened nudge through.
Key settings: NaturalRecoveryEnabled, AdaptiveQuietnessEnabled, MinimumNaturalDelaySeconds, MaximumNaturalDelaySeconds...
Cool Mode Restore
Puts the thermostat back into cool mode whenever someone switches it to heat/off/auto.
- Watches
- The Home Assistant HVAC mode, plus how far the room is above target.
- Effect
- Sends climate.set_hvac_mode = cool once the delay (if any) elapses.
Key settings: CoolModeRestoreDelayEnabled, CoolModeRestoreMinimumDelaySeconds, CoolModeRestoreMaximumDelaySeconds, CoolModeRestoreComfortBandCelsius
Natural Walkback
Walks a safe-band correction toward target in small, slightly random steps instead of one obvious jump.
- Watches
- Recent wall-touch pressure (a 0–100 suspicion score) and how far the setpoint is from the defender target.
- Effect
- Shapes the size of the setpoint command just before it is sent.
Key settings: NaturalWalkbackEnabled, NaturalWalkbackTriggerTouches, NaturalWalkbackStepCelsius, NaturalWalkbackJitterCelsius...
Touch Signature
Matches safe nudges to the size of steps people actually use on the wall thermostat.
- Watches
- The recent real wall-thermostat steps (their median size) inside the retention window.
- Effect
- Lowers the per-command nudge size used by Natural Walkback.
Key settings: TouchSignatureEnabled, TouchSignatureTriggerTouches, TouchSignatureRetentionMinutes, TouchSignatureMinimumStepCelsius...
Human Nudge
Makes the final safe setpoint command look like a normal thermostat step instead of a precise bot number.
- Watches
- Recent wall touches, the candidate defender command, the current thermostat setpoint, and room temperature.
- Effect
- Rewrites the outgoing safe setpoint to a normal one-step-looking value.
Key settings: HumanNudgeEnabled, HumanNudgeTriggerTouches, HumanNudgeStepCelsius, HumanNudgeSafetyBandCelsius
Visibility Guard
Slows the next safe nudge when a wall touch lands right after a defender command (someone likely noticed).
- Watches
- Wall touches that occur within the after-command window, counted as 'notices' over the notice window.
- Effect
- Delays the next safe correction so the AC's reaction looks less mechanical.
Key settings: VisibilityGuardEnabled, VisibilityGuardTriggerNotices, VisibilityGuardNoticeWindowMinutes, VisibilityGuardAfterCommandSeconds...
Routine Timing
Lines safe corrections up with a normal-looking comfort-check rhythm instead of firing instantly.
- Watches
- Recent wall touches and the wall-clock minute.
- Effect
- Delays the safe correction to the next tidy time slot.
Key settings: RoutineTimingEnabled, RoutineTimingTriggerTouches, RoutineTimingIntervalMinutes, RoutineTimingJitterMinutes...
Comfort Budget
Caps how many safe corrections happen inside a rolling window so the AC is not constantly nudged.
- Watches
- The count of recent automatic setpoint commands in the budget window.
- Effect
- Holds new safe corrections until the budget frees up.
Key settings: ComfortBudgetEnabled, ComfortBudgetWindowMinutes, ComfortBudgetMaxCommands, ComfortBudgetSafetyBandCelsius
Command Camouflage
Gives a recent helper command time to look normal before another safe correction appears.
- Watches
- The last real helper setpoint command, recent helper-command pressure, recent wall-touch pressure, and the room temperature.
- Effect
- Holds the next safe correction until the recent command has enough spacing.
Key settings: CommandCamouflageEnabled, CommandCamouflageMinimumGapSeconds, CommandCamouflagePressureExtraSeconds, CommandCamouflageSafetyBandCelsius
Stealth Governor
Runs a whole-system low-profile hold when wall touches, noticed corrections, remote changes, and helper commands make the defender look too busy.
- Watches
- Recent wall-touch pressure, noticed-correction pressure, Home Assistant remote-change pressure, helper command count, and room temperature.
- Effect
- Holds only safe corrections until the low-profile window ends.
Key settings: StealthGovernorEnabled, StealthGovernorTriggerScore, StealthGovernorMinimumHoldMinutes, StealthGovernorMaximumHoldMinutes...
Natural Cadence
Picks a variable future slot for safe nudges so they never land at identical, robotic times.
- Watches
- Recent wall-touch pressure and recent command pressure.
- Effect
- Delays the safe correction to the chosen cadence slot.
Key settings: NaturalCadenceEnabled, NaturalCadenceTriggerTouches, NaturalCadenceMinimumMinutes, NaturalCadenceMaximumMinutes...
Comfort Pace
The high-frequency planner: under heavy wall fighting it waits for a calm weather, sensor, or clock-aligned slot.
- Watches
- Touch pressure, command pressure, real outdoor-weather movement, the learned Home Assistant sensor beat, and 5/10-minute clock boundaries.
- Effect
- Delays the safe correction to the chosen calm climate slot.
Key settings: NaturalChangePlannerEnabled, NaturalChangePlannerTriggerTouches, NaturalChangePlannerMinimumMinutes, NaturalChangePlannerMaximumMinutes...
Comfort Envelope
Lets a tiny safe wall preference rest for a while instead of being corrected the instant it appears.
- Watches
- The wall setpoint relative to the defender target and how far the room is above target.
- Effect
- Suppresses the small correction while the wall preference is inside the safe range.
Key settings: ComfortEnvelopeEnabled, ComfortEnvelopeTriggerTouches, ComfortEnvelopeHoldMinutes, ComfortEnvelopeMaxOffsetCelsius...
Comfort Compromise
Blends a repeated wall choice into a temporary target, then fades it back to the website target.
- Watches
- The latest wall setpoint, the website target, and how far the room is above target.
- Effect
- Temporarily shifts the defender target the corrections aim for.
Key settings: ComfortCompromiseEnabled, ComfortCompromiseTriggerTouches, ComfortCompromiseHoldMinutes, ComfortCompromiseDecayMinutes...
Comfort Memory
Learns a small time-of-day target bias from repeated safe wall choices and re-applies it later that hour.
- Watches
- The current hour and the offsets learned for it; the room temperature.
- Effect
- Adjusts the defender target by the learned hourly bias.
Key settings: ComfortMemoryEnabled, ComfortMemoryLearningTouches, ComfortMemoryRetentionHours, ComfortMemoryMaxOffsetCelsius...
Conflict Quiet
Stands the defender down during an obvious tug-of-war over the thermostat.
- Watches
- Recent wall touches within the touch window and how far the room is above target.
- Effect
- Suppresses corrections for the stand-down period.
Key settings: ConflictQuietModeEnabled, ConflictQuietTouchThreshold, ConflictQuietMinutes, ConflictQuietComfortBandCelsius
Tug-of-War Truce
Calls a temporary truce when the real thermostat bounces up and down, so answer-back commands do not look like a duel.
- Watches
- The real external thermostat audit log: previous setpoint, new setpoint, timestamp, and source classification.
- Effect
- Holds safe corrections until the truce window ends, then lets the normal defender chain continue.
Key settings: TugOfWarTruceEnabled, TugOfWarTruceMinimumFlips, TugOfWarTruceWindowMinutes, TugOfWarTruceHoldMinutes...
Wall Settling
Waits for someone who is still tapping the wall thermostat to stop before correcting.
- Watches
- Recent touches inside the settling window and the room temperature.
- Effect
- Holds the correction until the wall stops changing.
Key settings: WallSettlingGuardEnabled, WallSettlingMinimumTouches, WallSettlingWindowMinutes, WallSettlingBaseSeconds...
Manual Comfort Grace
Leaves a manual wall change alone while the room still feels comfortable.
- Watches
- Time since the wall change and how far the room is above target.
- Effect
- Suppresses the correction while the wall change stays comfortable.
Key settings: ManualComfortGraceEnabled, ManualComfortGraceMinutes, ManualComfortGraceBandCelsius
Touch Intent
Reads whether recent wall changes trend warmer, cooler, or mixed, and extends grace for a clear warmer pattern.
- Watches
- The net sum of recent wall setpoint changes inside the intent window.
- Effect
- Lengthens Manual Comfort Grace when people clearly want warmer air.
Key settings: TouchIntentEnabled, TouchIntentMinimumTouches, TouchIntentWindowMinutes, TouchIntentNetWarmThresholdCelsius...
Cooler Intent Fast Lane
When people keep dialing the wall cooler, it skips quiet waits so the room cools sooner.
- Watches
- The net cooler movement of recent wall changes and whether the room is above target.
- Effect
- Bypasses the quiet timing guards for a short window.
Key settings: CoolerIntentFastLaneEnabled, CoolerIntentMinimumTouches, CoolerIntentWindowMinutes, CoolerIntentHoldMinutes...
Setpoint Echo
Waits for Home Assistant to report back the last setpoint before sending another safe command.
- Watches
- The pending command setpoint and whether Home Assistant has echoed it yet.
- Effect
- Briefly holds the next safe command to avoid piling commands on a slow integration.
Key settings: SetpointEchoGuardEnabled, SetpointEchoGraceSeconds, SetpointEchoSafetyBandCelsius
Repeat Quiet
Waits before sending the very same thermostat number again.
- Watches
- The setpoint about to be sent versus the last defender command, plus touch and command pressure.
- Effect
- Holds an identical follow-up command until the wait elapses.
Key settings: RepeatCommandGuardEnabled, RepeatCommandMinimumWaitSeconds, RepeatCommandPressureExtraSeconds, RepeatCommandSafetyBandCelsius
Setpoint Stillness
Waits until the wall setpoint stops moving before a safe correction answers back.
- Watches
- Real Home Assistant climate readings, the current reported setpoint, recent wall touches, and room temperature.
- Effect
- Delays only safe corrections until the wall setpoint looks settled.
Key settings: SetpointStillnessGuardEnabled, SetpointStillnessTriggerTouches, SetpointStillnessRequiredSamples, SetpointStillnessMaxHoldSeconds...
Sensor Rhythm
Times nudges to just after the normal Home Assistant reading beat so they look less mechanical.
- Watches
- Timestamps of real Home Assistant readings, used to learn the median update interval.
- Effect
- Delays the safe correction to align with the sensor's update cadence.
Key settings: SensorRhythmGuardEnabled, SensorRhythmMinimumSamples, SensorRhythmWindowMinutes, SensorRhythmJitterSeconds...
HVAC Alibi
Waits for a real HVAC action transition so a safe correction lands near a normal thermostat event.
- Watches
- The current Home Assistant hvac_action, the last action transition, recent wall touches, and room temperature.
- Effect
- Delays only safe corrections until a real HVAC action transition or the max hold expires.
Key settings: HvacActionAlibiEnabled, HvacActionAlibiTriggerTouches, HvacActionAlibiTransitionWindowSeconds, HvacActionAlibiMaxHoldMinutes...
Telemetry Alibi
Waits for a normal Home Assistant/weather/usage update before a safe correction, so the nudge is not an isolated event.
- Watches
- Recent wall touches, real Home Assistant reading beats, weather samples, Alectra Hui usage updates, and room temperature.
- Effect
- Delays only safe corrections until a normal house telemetry update can act as cover.
Key settings: TelemetryAlibiEnabled, TelemetryAlibiTriggerTouches, TelemetryAlibiMinimumHoldSeconds, TelemetryAlibiMaxHoldMinutes...
Cooling Runway
Gives the AC time to work after cooling starts before nudging the setpoint again.
- Watches
- The Home Assistant hvac_action and how long ago cooling started, plus command pressure.
- Effect
- Holds the next safe nudge so a fresh cooling cycle is not interrupted.
Key settings: CoolingRunwayGuardEnabled, CoolingRunwayMinimumSeconds, CoolingRunwayPressureExtraSeconds, CoolingRunwaySafetyBandCelsius
Room Trend Guard
Keeps observing when the room is already stable or cooling after a wall change.
- Watches
- Real room-temperature samples: the oldest versus newest inside the trend window.
- Effect
- Holds the correction while the room is trending cooler on its own.
Key settings: RoomTrendGuardEnabled, RoomTrendWindowMinutes, RoomTrendStableToleranceCelsius, RoomTrendHoldMinutes
Thermal Momentum
Waits when the room is already cooling fast enough to reach target soon on its own.
- Watches
- Real room-temperature samples (to estimate cooling rate) and the active cooling action.
- Effect
- Holds the correction so existing momentum can finish the job.
Key settings: ThermalMomentumGuardEnabled, ThermalMomentumMinimumCoolingRateCelsiusPerHour, ThermalMomentumLookAheadMinutes, ThermalMomentumHoldMinutes
Weather Drift Timing
Times safe corrections to real outdoor-weather movement instead of firing immediately.
- Watches
- Real outdoor-temperature samples (oldest versus newest) inside the weather window.
- Effect
- Holds the safe correction until outdoor weather moves.
Key settings: WeatherDriftGuardEnabled, WeatherDriftWindowMinutes, WeatherDriftMinimumChangeCelsius, WeatherDriftHoldMinutes...
Website Debounce
Blocks repeated website button taps for two minutes so the UI does not spam Home Assistant.
- Watches
- The last website command name and time.
- Effect
- Rejects duplicate website actions until the window clears.
Key settings: (fixed at 120 seconds)
Super Defender
Detects repeated phone/Home Assistant thermostat changes and tightens correction timing without cutting thermostat Wi-Fi.
- Watches
- Home Assistant context on climate state changes: user_id, parent_id, and context id.
- Effect
- Shows source attribution, arms a strict response window, and can bypass quiet timing while cooling is needed.
Key settings: SuperDefenderModeEnabled, SuperDefenderRemoteChangeThreshold, SuperDefenderWindowMinutes, SuperDefenderHoldMinutes...
Rival Schedule Watch
Knows the AC vendor app's own temperature schedule (SLEEP / DEEP SLEEP / GOOD MORNING) and defends my temp when a scheduled block pushes the wall warmer while everyone sleeps.
- Watches
- The configured rival AC-app schedule blocks (start time + low/high setpoints per weekday), the live wall setpoint, Home Assistant change context, and the local clock.
- Effect
- Attributes schedule pushes in the audit log, announces block boundaries as events, and answers a scheduled warm push back toward my temp without human-style delays.
Key settings: RivalScheduleWatchEnabled, RivalScheduleSetpointToleranceCelsius, RivalScheduleBypassQuietTiming, RivalScheduleSafetyBandCelsius...
Cool-Outdoor Shutdown (Open-Window Armistice)
When it is genuinely cool outside and the forecast says it stays cool, the defender turns the AC fully off — and turns it back on by itself when the weather or the room demands it.
- Watches
- The real outdoor temperature, the hourly Home Assistant forecast over the gate hours, the room temperature, the thermostat mode, and the minimum-off dwell clock.
- Effect
- Sends climate.set_hvac_mode = off once per cool episode, then a tagged automatic restore.
Key settings: CoolOutdoorShutdownEnabled, CoolOutdoorShutdownBelowCelsius, CoolOutdoorRestoreMarginCelsius, CoolOutdoorMinimumOffMinutes...
Siesta Watch (mess hall)
Lets the whole guard force nap on command; while they sleep the AC eases off and the money it would have spent is banked as food rations.
- Watches
- The siesta timer, the room temperature against the wake band, the budget safety maximum, and the thermostat mode.
- Effect
- Holds the whole correction pipeline while the nap timer runs; sends one park/off command at the start.
Key settings: SiestaEnabled, SiestaThermostatAction, SiestaWakeBandCelsius, SiestaMaxMinutes
Field Kitchen (food rations)
Banks unspent AC dollars during siestas and cool-outdoor shutdowns, and spends them on forecast-hot days so the monthly budget eases exactly when cooling matters most.
- Watches
- The pantry balance and cap, the trailing-week compressor duty cycle, the Alectra TOU rate in force, the hourly forecast over the release lookahead, and the AC's real per-slice estimated cost.
- Effect
- Adjusts the monthly budget's over/under bookkeeping; moves no real money and sends no thermostat commands.
Key settings: FoodRationsEnabled, FoodBalanceMaxCad, FoodReleaseHotThresholdCelsius, FoodReleaseLookaheadHours...
Desired-State Enforcer
Makes the owner's chosen AC state win automatically: if someone else turns the unit off or moves the setpoint, it restores the exact desired state and keeps it there.
- Watches
- Home Assistant HVAC mode, the live setpoint vs the owner's target, context.user_id attribution, recent override/assert counts, and the learned interference probability.
- Effect
- Restores the desired mode/setpoint, escalates on repeated interference, and notifies — using the trained interference/cadence models to pace itself.
Key settings: EnforcerModeEnabled, EnforcerTargetTemperatureCelsius, EnforcerEnforceMode, EnforcerEnforceSetpoint...
Remote Settling Guard
Gives repeated phone/Home Assistant or automation thermostat changes a quiet settling window before a safe answer-back.
- Watches
- Home Assistant change source attribution, recent remote-style change count, room temperature, and the expected setpoint.
- Effect
- Delays only safe corrections after remote-style thermostat changes so the response does not look instant.
Key settings: RemoteSettlingGuardEnabled, RemoteSettlingTriggerChanges, RemoteSettlingWindowMinutes, RemoteSettlingHoldMinutes...
Alectra Peak Power Saver
Makes the defender more chill and resource-saving when Alectra Hui reports on-peak, high price, or high power use.
- Watches
- Alectra Hui current TOU period, current price, current power, and current plan sensors from Home Assistant.
- Effect
- Holds safe cooling during expensive/high-load periods and prefers the saver fan mode.
Key settings: PeakPowerSaverEnabled, PeakPowerSaverOnPeakEnabled, PeakPowerSaverHighPowerEnabled, PeakPowerSaverPowerThresholdKilowatts...
Front-door Guard Post
Pauses the defender and can turn the thermostat off when a real front-door person detector trips.
- Watches
- Configured or auto-discovered Home Assistant front-door person sensors.
- Effect
- Runs the kill switch, hides the live boards while paused, and records the source.
Key settings: FrontDoorKillSwitchEnabled, FrontDoorPersonEntityIds, FrontDoorKillSwitchHoldMinutes, FrontDoorKillSwitchRefreshSeconds...
Emergency Protocols
One-tap stand-down modes for too-cold, someone-upset, and suspicion situations.
- Watches
- The chosen protocol and its remaining window.
- Effect
- Suppresses corrective commands for the protocol window.
Key settings: (run from the Controls page)
Cooling Failure Watch
Raises a repeating mega-alert when cool mode is demanded but the AC is not really cooling, escalates to a full-site OMEGA alert when a rising room confirms it, then turns the AC off until the room warms 0.5 C.
- Watches
- Real Home Assistant data only: hvac_mode, hvac_action, the setpoint, and room-temperature history.
- Effect
- Surfaces a red alert, an event log entry, and (on OMEGA) a site-wide overlay. It also turns the AC fully off (a failing unit is only wasting power) and holds it off until the real room temperature rises 0.5 C above the reading captured at shutdown, then restores cool. A human turning the AC back on is always respected.
Key settings: CoolingFailureWatchEnabled
Dynamic Cooldown
A frequency-based quiet period after a manual thermostat change.
- Watches
- How many wall touches happened recently inside the touch-frequency window.
- Effect
- Holds the next correction until the cooldown elapses.
Key settings: BaseCooldownSeconds, MaxCooldownSeconds, TouchFrequencyWindowMinutes
Fan Energy Saver
Optionally moves the fan to an energy-saving mode when the room is near target.
- Watches
- Room temperature versus target and the thermostat's available fan modes.
- Effect
- Sets the fan to the saver mode; otherwise leaves the fan alone.
Key settings: FanEnergySaverEnabled, FanEnergySaverThresholdCelsius, FanEnergySaverMode
Upstairs Comfort Guard
Prioritizes cooling when upstairs rooms get hot while someone is home.
- Watches
- The hottest configured (or auto-discovered) upstairs temperature sensor and optional presence entities.
- Effect
- Lowers the effective target and can bypass quiet timing.
Key settings: UpstairsComfortEnabled, UpstairsTemperatureEntityIds, UpstairsMaxComfortCelsius, UpstairsComfortTargetCelsius...
Schedule & Weather Rules
Time-of-day target rules, each gated by a weather activation condition.
- Watches
- The active schedule entry for the current day/time and the weather rule.
- Effect
- Sets the target and whether corrective action runs.
Key settings: ScheduleEnabled, WeatherActivationMode, (per-rule Days / Start / End / Target / Weather)
Repeated-Raise Surrender
If a person re-raises the setpoint to about the same value 3+ times in 30 minutes, the defender adopts their number for 4 hours — the human wins the argument.
- Watches
- Recent external RAISES (times and values, pruned to a 30-minute window).
- Effect
- Raises the effective target to the human's number for 4 hours and logs the surrender.
Key settings: (always on — fixed: 3 raises / 30 min window / 4 h hold / 27 C cap)
Tamper Truce
If the thermostat vanishes right after a correction exchange, assume a frustrated person detached it — stand down 2 hours instead of escalating.
- Watches
- Home Assistant reachability, the last defender command time, and recent human touches.
- Effect
- Raises the ULTRA OMEGA ALERT, activates a 2-hour stand-down, and records the tamper-truce event.
Key settings: (always on — fixed: 20 min command window / 45 min touch window / 2 h truce)
Wake-Up Truce (door sensor)
A bedroom door opening at dawn means that person is awake — adopt the warm truce temperature before they ever touch the thermostat.
- Watches
- The configured bedroom door sensor (closed-to-open transitions) during the dawn window.
- Effect
- Adopts the truce target for the hold period and logs a friendly good-morning event.
Key settings: WakeTruceDoorSensorEntityId, WakeTruceWindowStart, WakeTruceWindowEnd, WakeTruceTargetCelsius...
Failure modes
If Algorithms cannot obtain one of its required real inputs, it reports a blocked, held, or unavailable result and leaves the background worker’s Home Assistant refresh running. It never fills a missing room reading, audit event, weather sample, usage value, or device state with a simulator value. If a real Home Assistant command is rejected, the user sees the service’s actual error and the article’s surface remains available for recovery.
Security considerations
This feature consumes only the configured Home Assistant entity data, local settings, and the audit context named above. Tokens and credentials stay in the server environment; the static documentation site does not collect analytics, transmit search text, or embed third-party assets. Logs and exports should be reviewed before sharing because real entity names and timestamps can identify a household.
Verification
Verify the shipped behavior at the feature’s live page or endpoint, then run the repository’s documented build and test commands. Confirm the real-input and real-error paths, keyboard access, reduced-motion behavior, and a 390 px viewport without horizontal overflow. Record the exact commit and workflow result when publishing a release; a static screenshot alone is not proof of a live Home Assistant command.
Suggested articles
- Feature briefs — find every documented surface and guard.
- Defender Logic — follow the complete decision cycle and its bypass rules.
- Settings — inspect persisted configuration, language modes, and safety limits.